The Protocentral easyECG is a single-lead ECG breakout built from parts you can point at and probe. This guide takes you from the box to a heartbeat in the OpenView desktop app, by way of the wiring, the electrodes and the one safety rule that matters most.
Research use only. easyECG is for education, research and experimentation. It is not a medical device and must not be used for diagnosis or monitoring of any medical condition.
Before you put electrodes on anyone
easyECG has no isolation. With electrodes on a person, the host must run from a battery, or connect through an easyISO isolated Qwiic adapter.
On a mains-powered computer, leakage current through the USB ground drives the right-leg circuit to its rail, and you get a flat line, not a noisy trace. A laptop on battery is fine, as long as its charger is unplugged.
The same applies to test equipment. A mains-earthed bench scope connects the person wearing the electrodes to earth, so probe with a battery-powered scope, or use an ECG simulator instead of a person.
Introduction
An ECG electrode picks up about a millivolt of heart signal, sitting on an offset that can be a hundred times larger. Most ECG boards handle this inside one chip, so all you see is the output. easyECG does it in stages:
- A TI INA333 instrumentation amplifier takes the difference between the left-arm and right-arm electrodes, with a gain of ×11.
- An RC high-pass at about 0.5 Hz removes the electrode offset.
- A TI OPA2333 op-amp adds a gain of ×48.6, for ×535 in total.
- A Sallen-Key low-pass limits the band to about 31 Hz.
- A TI TLA2024 12-bit ADC digitises the result and sends it over I²C.
- A further OPA2333 stage and a third electrode form the right-leg drive, which holds the body near the amplifier’s common mode.
The whole chain is printed on the back of the board, and each stage has a test point on the front. The Arduino library finishes the job in software, with a 50/60 Hz notch, a 40 Hz low-pass and heart-rate detection.
Key Features
- Discrete, probeable front end: INA333, OPA2333 and TLA2024, with every stage labelled.
- Labelled test points: INA OUT, OUT, DRL and VMID, plus a GND point for your probe clip.
- Two Qwiic / STEMMA QT ports for daisy-chaining, plus a 0.1″ header for 3.3 V or 5 V hosts.
- Filters and heart rate in the library: mains notch, low-pass and Pan-Tompkins beat detection.
- Shares a bus with easyEMG: easyECG ships at 0x49 and easyEMG at 0x48.
- Open hardware (CERN-OHL-P v2) and an MIT-licensed library.
What’s in the Box

| Qty | Item |
|---|---|
| 1 | Protocentral easyECG breakout board |
| 1 | 1×4 0.1″ header (not soldered) |
| 1 | 3-lead snap electrode cable, 3.5 mm TRS |
| 10 | Disposable Ag/AgCl snap electrodes |
A Qwiic cable and a host board are not included.
Specifications
| Parameter | Value |
|---|---|
| Lead | Single lead (Lead I), 3 electrodes (LA, RA, RL) |
| Gain | ×535 total (×11 in-amp, ×48.6 second stage) |
| Analog bandwidth | 0.5 – 31 Hz (−3 dB) |
| Input range | ±3.1 mV; electrode offset tolerance ±145 mV |
| ADC | TI TLA2024, 12-bit, ±2.048 V range |
| Resolution | 1.87 µV per count at the electrodes |
| Sample rate | 1 kSPS paced by the library; 500 SPS on 8-bit AVR Arduinos |
| Interface | I²C / Qwiic, address 0x49 (0x48 via the ADDR jumper) |
| Supply | 3.3 V on Qwiic; 3.3 – 5 V on the header |
| Right-leg current limit | 390 kΩ (≤ 4.2 µA into the body) |
| Board | 40.0 × 28.8 mm, 4 × M2 mounting holes |
Hardware Overview

| Test point | What you’ll see there |
|---|---|
| INA OUT | The in-amp output, ×11, including the electrode offset |
| OUT | The final signal going into the ADC, ×535, centred on VMID |
| VMID | The buffered 1.65 V mid-rail that the signal is centred on |
| DRL | The right-leg drive output |
| GND | Ground, for your probe clip |

I²C address
The board ships at 0x49. To move it to 0x48, cut the bridge on the ADDR jumper and bridge the 0x48 side, then construct the library object with easyECG ecg(EASYECG_I2C_ADDR_ALT);.
Wiring
Option 1 — Qwiic (solderless)
Connect a Qwiic / STEMMA QT cable from your board’s Qwiic port to either port on easyECG. That’s all: the cable carries power, ground, SDA and SCL. The Qwiic port runs at 3.3 V.

On some boards the Qwiic port is a second I²C bus. On an Arduino UNO R4 WiFi, for example, it’s Wire1, so call ecg.begin(Wire1); and Wire1.setClock(400000);.
Option 2 — I²C over the 0.1″ header
No Qwiic port? easyECG needs only two I²C lines plus power and ground. Solder the included header and wire it up:
| easyECG pin | Arduino Uno / Nano | ESP32 (default I²C) | Raspberry Pi Pico | Raspberry Pi |
|---|---|---|---|---|
| VCC | 5V | 3.3V | 3V3 OUT (pin 36) | 3V3 (pin 1) |
| GND | GND | GND | GND (pin 38) | GND (pin 6) |
| SDA | A4 | GPIO21 | GP4 (pin 6) | GPIO2 (pin 3) |
| SCL | A5 | GPIO22 | GP5 (pin 7) | GPIO3 (pin 5) |
SCL is the square pad. The header takes 3.3 – 5 V and has its own regulator and level shifting, so a 5 V Arduino can drive it directly. On the Pico and the Raspberry Pi, use the MicroPython driver rather than the Arduino library.
Through easyISO
For a mains-powered host, connect the host to the IN side of an easyISO and easyECG to the OUT side. No code changes are needed. See the easyISO guide.
Placing the electrodes
Plug the cable into the 3.5 mm jack and snap a fresh electrode onto each lead.

| Lead | Colour | Jack contact | Chest (recommended) | Limb |
|---|---|---|---|---|
| LA | Green | Sleeve | Below the left collarbone | Left wrist or forearm |
| RA | Red | Ring | Below the right collarbone | Right wrist or forearm |
| RL | Yellow | Tip | Lower right abdomen, or over the hip bone | Right leg or ankle |
Chest placement gives a larger R-wave than wrists, and it keeps forearm muscle noise out of the trace. For a clean signal:
- Wipe the skin with alcohol and let it dry.
- Twist the three leads together.
- Sit still with your arms relaxed and supported.
- Give the gel a minute or two to settle.
Installing the library
- In the Arduino IDE, open Tools → Manage Libraries.
- Search for ProtoCentral easyECG and click Install.
Or download the library from GitHub and use Sketch → Include Library → Add .ZIP Library. It has no other dependencies.
Seeing your first heartbeat
OpenView is our desktop app for live plotting and recording, and it’s the way to see the ECG. The Arduino Serial Plotter can’t keep up with the sample rate, so the trace isn’t visible there.
- Install OpenView, and keep your laptop on battery with the charger unplugged.
- Upload File → Examples → ProtoCentral easyECG → 04.OpenView. Sit still for the first second while it zeroes the baseline.
- Close any Serial Monitor or Serial Plotter window, because they hold the port.
- In OpenView, open Connect and choose USB. Select easyECG Breakout on OpenView 3.4 or later, or ADS1292R Breakout on earlier versions. Don’t select MAX86150: its baud rate doesn’t match, so it never locks on.

Reading the trace
You should see a repeating heartbeat: a small P wave, the tall narrow QRS spike, then a broader T wave. The heart rate needs about two seconds to learn your signal level, and a few beats more to settle. Until then it has no reading.
If the trace is upside down, LA and RA are swapped.
On OpenView 3.4 or later, two tiles sit beside the trace:
- Heart rate, in bpm.
- Signal, the library’s check on the electrodes: OK, Lead-off or mains pickup, or Amplifier saturated.
When the signal isn’t OK, the heart-rate tile dims, because a reading from a bad signal can’t be trusted. A loose or missing electrode looks like this:

Press the electrode back on and give the trace a few seconds. The warning clears, and the heart rate comes back a few beats later.
Paper draws an ECG-paper grid at a fixed scale, printed at the bottom of each strip; Gain changes it. Auto fits the trace to the strip instead.
Before OpenView 3.4, the ADS1292R Breakout profile keeps its own labels, so here’s what each one means for easyECG:
| OpenView shows | Actually is |
|---|---|
| ECG | Filtered ECG, in counts |
| Respiration | Unfiltered ECG, so you can see what the filters remove |
| heartRate | Heart rate, bpm |
| respRate | Signal status: 0 = OK, 1 = lead-off or mains pickup, 2 = amplifier saturated |
Using the library in your own sketch
This sketch prints the filtered ECG and heart rate, as a starting point for your own code:
#include <Wire.h>
#include "ProtoCentral_easyECG.h"
easyECG ecg;
void setup() {
Serial.begin(115200);
if (!ecg.begin()) {
Serial.println("easyECG not found - check wiring and I2C address (0x49).");
while (1) delay(1000);
}
Wire.setClock(400000);
// ecg.setNotch(60.0f); // uncomment where mains is 60 Hz
ecg.calibrateBaseline(1000); // one second, sitting still
}
void loop() {
if (ecg.update()) { // true each time a filtered sample is ready
Serial.print("ECG_uV:");
Serial.print(ecg.ecgMicrovolts(), 1);
Serial.print(",BPM:");
Serial.println(ecg.heartRate(), 0);
}
}
Disconnect the charger if you’re on a laptop, upload the sketch, then open Tools → Serial Monitor at 115200 baud.
Call update() as often as you can and keep the rest of loop() short. The filters are built for an exact sample rate, so update() samples on a fixed clock and never blocks.
Microvolt readings use the design gain of ×535. The trace shape and heart rate don’t depend on it.
Other examples
Find these under File → Examples → ProtoCentral easyECG:
| Example | What it does |
|---|---|
01.BasicReading |
Filtered ECG in counts and µV |
02.SerialPlotter |
Filtered and unfiltered values for the Serial Plotter, which can’t keep up with the sample rate; use 04.OpenView to see the ECG |
03.HeartRate |
Heart rate on every beat, with an LED blink and signal-quality messages |
04.OpenView |
Streams to the OpenView desktop app |
05.Diagnostics |
I²C scan, config read-back, ADC check, then noise, mains and heart rate every 2 s |
Troubleshooting
Start with 05.Diagnostics. It reports whether the board is on the bus, whether the configuration took, and what the signal is doing.
| Symptom | Likely cause | What to try |
|---|---|---|
| “easyECG not found” | Wiring, or a different address | Check the cable and run 05.Diagnostics. The board ships at 0x49 |
| Flat line, saturated | Mains-powered host | Unplug the charger, or use an easyISO |
| Flat line, saturated | Electrode off | Check all three snaps and pads |
| Small R-wave | Limb placement | Move to the chest positions |
| Busy baseline between beats, little mains | Muscle tension or poor contact | Relax, re-prep the skin, use fresh electrodes |
| Strong mains hum | Loose electrode, long untwisted leads, a nearby mains cable, or the wrong notch | Fix the contact, twist the leads, and set the notch to your mains frequency |
missedSamples() keeps growing |
loop() is doing too much |
Shorten it, or lower the ADC rate with setSampling() |
| Inverted trace | LA and RA swapped | Swap the two electrodes |
Where next
- Product page: Protocentral easyECG
- Arduino library: protocentral_easyecg_arduino
- MicroPython and Raspberry Pi driver: protocentral-micropython-easyecg
- Schematic and KiCad files: schematic (PDF) · hardware repo
- Datasheets: INA333 · OPA2333 · TLA2024
- Isolation: easyISO isolated Qwiic adapter
- Muscle signals on the same bus: Protocentral easyEMG